Difference between LR DH62 and LR EH62 steel plate

Jan 26, 2026 Lämna ett meddelande

LR DH62 and LR EH62 are both high-strength, Lloyds Register (LR) certified shipbuilding steel grades with the same yield strength 620 MPa, tensile strength 720-890 MPa, and chemical composition. The primary difference is their notch toughness: EH62 is tested at lower temperatures -40℃ C compared to DH62 -20℃ C, making EH62 better suited for arctic conditions.

 

LR DH62 extra high Strength Chemical Composition

C

P

S

N

LR DH62

0.20

0.55

1.70

0.030

0.030

0.015

0.020

V

0.02-0.05

0.03-0.10

0.02

 

 

 

 

 

LR EH62 extra high Strength Chemical Composition

C

P

S

N

LR EH62

0.20

0.55

1.70

0.030

0.030

0.015

0.020

V

0.02-0.05

0.03-0.10

0.02

 

 

 

 

 

 

LR DH62 extra high strength property

 

Energy 1

Energy 2

LR DH62

-20

J

J

t<=50

620

720-890

17%

41

62

50<t<=70

620

720-890

17%

41

62

70<t<=100

620

720-890

17%

41

62

Note: Energy 1 is transverse impact test, Energy 2 is longitudinal

 

LR EH62 extra high strength property

 

Energy 1

Energy 2

LR EH62

-40

J

J

t<=50

620

720-890

17%

41

62

50<t<=70

620

720-890

17%

41

62

70<t<=100

620

720-890

17%

41

62

Note: Energy 1 is transverse impact test, Energy 2 is longitudinal

 

LR DH62: "D" signifies Charpy V-Notch impact testing at -20℃ C.

LR EH62: "E" signifies Charpy V-Notch impact testing at -40℃ C.

Strength: Both have a minimum yield strength of 620 MPa and a tensile strength range of 720-890 MPa.

Application: Both are used for heavy-duty ship structures, but EH62 is required for colder, more extreme environments.