LR DH62 and LR EH62 are both high-strength, Lloyds Register (LR) certified shipbuilding steel grades with the same yield strength 620 MPa, tensile strength 720-890 MPa, and chemical composition. The primary difference is their notch toughness: EH62 is tested at lower temperatures -40℃ C compared to DH62 -20℃ C, making EH62 better suited for arctic conditions.
|
LR DH62 extra high Strength Chemical Composition |
|||||||
|
C |
P |
S |
N |
||||
|
LR DH62 |
0.20 |
0.55 |
1.70 |
0.030 |
0.030 |
0.015 |
0.020 |
|
V |
|||||||
|
0.02-0.05 |
0.03-0.10 |
0.02 |
|
|
|
|
|
|
LR EH62 extra high Strength Chemical Composition |
|||||||
|
C |
P |
S |
N |
||||
|
LR EH62 |
0.20 |
0.55 |
1.70 |
0.030 |
0.030 |
0.015 |
0.020 |
|
V |
|||||||
|
0.02-0.05 |
0.03-0.10 |
0.02 |
|
|
|
|
|
|
LR DH62 extra high strength property |
|||||||
|
|
|||||||
|
Energy 1 |
Energy 2 |
||||||
|
LR DH62 |
-20 |
J |
J |
||||
|
t<=50 |
620 |
720-890 |
17% |
41 |
62 |
||
|
50<t<=70 |
620 |
720-890 |
17% |
41 |
62 |
||
|
70<t<=100 |
620 |
720-890 |
17% |
41 |
62 |
||
|
Note: Energy 1 is transverse impact test, Energy 2 is longitudinal |
|||||||
|
LR EH62 extra high strength property |
|||||||
|
|
|||||||
|
Energy 1 |
Energy 2 |
||||||
|
LR EH62 |
-40 |
J |
J |
||||
|
t<=50 |
620 |
720-890 |
17% |
41 |
62 |
||
|
50<t<=70 |
620 |
720-890 |
17% |
41 |
62 |
||
|
70<t<=100 |
620 |
720-890 |
17% |
41 |
62 |
||
|
Note: Energy 1 is transverse impact test, Energy 2 is longitudinal |
|||||||
LR DH62: "D" signifies Charpy V-Notch impact testing at -20℃ C.
LR EH62: "E" signifies Charpy V-Notch impact testing at -40℃ C.
Strength: Both have a minimum yield strength of 620 MPa and a tensile strength range of 720-890 MPa.
Application: Both are used for heavy-duty ship structures, but EH62 is required for colder, more extreme environments.